What fuse is on the socket?This is where most people fall
The rule: amps × 230 = watts. It applies to the whole circuit, not the socket. It assumes 230 V, as in Europe and the UK.
| Circuit rating | Limit for everything on the circuit |
|---|---|
| 10 A | about 2,300 W |
| 16 A | about 3,700 W |
| Three-phase 16 A | about 11,000 W |
Work it out yourself:
| Item | Watts |
|---|---|
| = total | |
| Is the total under the limit? |
Enter the roaster’s power and we will do the maths.
Three-phase: a single-phase machine still only gets about 3,680 W on its phase, so choose 16 A.

The trap: the socket in your back room shares a circuit with the dishwasher, the kettle or the fridge. Find the circuit list in the fuse board. If it is not there, ask your electrician.
Calculate with the machine’s peak power, not its average. Most roasters draw the most while heating up. A machine close to the circuit’s limit should have the circuit to itself.
If the circuit is shared with the kettle or the microwave, a routine can also solve it: do not use them while the machine roasts, and put up a note. Or run the roaster from another circuit.
Ask your electrician: What is the circuit rated at, what else is on it, and can the roaster have a circuit where nothing else large runs?